    CMP/Hawke防爆格蘭,CCG/Peppers防爆格蘭,Eaton/Cooper/OCSG防爆格蘭防爆接線箱等

    新聞中心
    • 暫無新聞
    產品分類
    站內搜索
     
    您當前的位置:首頁 » 供應產品 » Hawke鎧裝防爆格蘭(501/453/Univ系列)
    Hawke鎧裝防爆格蘭(501/453/Univ系列)
    點擊圖片查看大圖
    產 品: 瀏覽次數:174Hawke鎧裝防爆格蘭(501/453/Univ系列) 
    品 牌: Hawke鎧裝防爆格蘭(501/453/Univ系列) 
    單 價: 面議 
    最小起訂量:  
    供貨總量:
    發貨期限: 自買家付款之日起 3 天內發貨
    更新日期: 2025-03-31 09:20  有效期至:長期有效
      詢價
    詳細信息
    Hawke鎧裝防爆密封接頭(501/453/Univ系列)
    Hawke鎧裝防爆格蘭密封接頭(501/453/Univ系列)

    HAWKE 501/453/UNIVERSAL CABLE GLANDS

     

    portant;">HAWKE鎧裝防爆格蘭(501/453/UNIV系列)

    portant;"> 

    Hawke 501/453/Universal Cable Glands

    Hazardous Area Cable Glands from Hawke

         Hawke鎧裝防爆格蘭/密封接頭/填料函(501/453/Univ-Hawke Cable Gland)

    Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

    Hawke防爆格蘭代理商:上海頤品自動化科技有限公司(4008552521)

    關鍵詞:Hawke防爆格蘭,Hawke防爆變徑,Hawke防爆堵頭,Hawke防爆呼吸閥,Hawke防爆接線盒,Hawke防爆控制箱

    Hawke防爆格蘭等產品規格書及相關證書-請咨詢上海頤品自動化科技有限公司

     

    portant;">Hawke 501/453/Universal cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables. Mainly used with cables that show ‘cold flow’ characteristics.

    portant;">Hawke 501/453/Universal cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.5-91.6mm outside cable diameters.

    portant;">When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

    portant;">♦ Exdb IIC Gb, Exeb IIC Gb, ExnR IIC Gc, Extb IIIC Db Aromoured Cables ATEX & IECEx Cable Gland.

    portant;">Hawke 501/453/Universal cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

    • Flameproof Exdb
    • Increased Safety Exeb
    • Restricted Breathing ExnR
    • Dust Extb
    • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

    HAWKE 501/453/UNIVERSAL CABLE GLAND TECHNICAL SPECIFICATION

    1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, ExnR IIC Gc, Extb IIIC Db
    2. Certificate No’s  – baseefa06ATEX0057X and IECEx BAS 06.0014X
    3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC
    4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31
    5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
    6. Deluge Protection – DTS01
    7. Operating Temperature Range  -60°C to +80°C

    CABLE GLAND SELECtION TABLE FOR HAWKE 501/453/UNIVERSAL

    Hawke
    Size
     
    Ref.
    Entry Thread Size Thread 
    Length
     
    ‘H’
    Cable Acceptance Details ‘G’ 
    Compressed
     
    Length
    Hexagon Dimensions
    Inner Sheath ‘A’ Outer Sheath ‘B’ ‘C’ Armour/Braid
    Metric NPT * Across 
    Flats
    Across 
    Corners
    Standard Option Min. Max. Min. Max. Orienta
    tion
     1
    Orienta
    tion
     2
    Os M20 ‡ ½” 15 3.5 8.1 5.5 12.0 0.8 / 1.25 0 / 0.8 61.6 24.0 26.5
    O M20 ‡ ½” 15 6.5 11.4 9.5 16.0 0.8 / 1.25 0 / 0.8 61.6 24.0 26.5
    A M20 ¾” ½” 15 8.4 14.3 12.5 20.5 0.8 / 1.25 0 / 0.8 63.0 30.0 32.5
    B M25 1″ ¾” 15 11.1 19.7 16.9 26.0 1.25 / 1.6 0 / 0.7 69.9 36.0 39.5
    C M32 1¼” 1″ 15 17.6 26.5 22.0 33.0 1.6 / 2.0 0 / 0.7 73.2 46.0 50.5
    C2 M40 1½” 1¼” 15 23.1 32.5 28.0 41.0 1.6 / 2.0 0 / 0.7 77.9 55.0 60.6
    D M50 2″ 1½” 15 28.9 44.4/42.3 † 36.0 52.6 1.8 / 2.5 0 / 1.0 93.5 65.0 70.8
    E M63 2½” 2″ 15 39.9 56.3/54.3 † 46.0 65.3 1.8 / 2.5 0 / 1.0 94.0 80.0 88.0
    F M75 3″ 2½” 15 50.5 68.2/65.3 † 57.0 78.0 1.8 / 2.5 0 / 1.0 103.0 95.0 104.0
    G M80 3½” 20 67.0 73.0 75.0 89.5 2.0 / 3.5 0 / 1.0 90.6 106.4 115.0
    H M90 3½” 20 67.0 77.6 75.0 89.5 2.0 / 3.5 0 / 1.0 90.6 115.0 130.0
    J M100 4″ 20 75.0 91.6 88.0 104.5 2.5 / 4.0 0 / 1.0 90.6 127.0 142.0

    portant;">Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
    † Smaller value is applicable when selecting reduced NPT entry option.
    Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.

    CABLE GLAND MATERIAL & FINISH

    portant;">Hawke 501/453/Universal cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

    PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/453/UNIVERSAL

    portant;">Hawke 501/453/Universal - Cable & Gland Preparation

    CABLE PREPARATION

    portant;">Strip cable to suit equipment as shown above and expose the armour/braid ‘I’.

    portant;">‘I’ = 20mm for cable gland sizes Os to C ‘I’ = 25mm for cable gland sizes C2 to H & J ‘II’ = to suit equipment.

    CABLE GLAND PREPARATION

    portant;">Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. Position the armour clamping ring (3).

    portant;">Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6). Note: If the equipment has a threaded entry, it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step D

    portant;">Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

    Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

    • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing
    • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath
    • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas
    • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas
    • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas
          Hawke鎧裝防爆格蘭(Hawke Cable Gland)

    Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

    Hawke防爆格蘭代理商:上海頤品自動化科技有限公司(4008552521)
          關鍵詞:Hawke防爆格蘭,Hawke防爆變徑,Hawke防爆堵頭,Hawke防爆呼吸閥,Hawke防爆接線盒,Hawke防爆控制箱

    Hawke防爆格蘭等產品規格書及相關證書-請咨詢上海頤品自動化科技有限公司

         上海頤品代理Hawke鎧裝防爆格蘭密封接頭(501/453/Univ系列) 
    詢價單
    網站首頁  | 公司介紹  | 供應產品  | 新聞中心  | 聯系方式  | 管理入口
    ©2025 上海頤品自動化科技有限公司 版權所有   技術支持:機交網     訪問量:4279
    主站蜘蛛池模板: 国产成人亚洲综合一区| 综合久久给合久久狠狠狠97色| 伊人狠狠色丁香综合尤物| 狠狠色色综合网站| 色婷婷综合中文久久一本| 国产综合精品一区二区| 伊人久久大香线焦AV综合影院| 亚洲综合视频在线| 亚洲国产免费综合| 色狠狠久久综合网| 久久综合狠狠综合久久| 思思91精品国产综合在线| 色欲久久久天天天综合网| 国产成人综合色在线观看网站| 色综合久久中文综合网| 人人狠狠综合久久亚洲88| 色综合天天综合婷婷伊人| 91在线亚洲综合在线| 亚洲国产国产综合一区首页| 国产激情电影综合在线看| 大香网伊人久久综合观看| 色综合天天综合高清网| 五月天婷五月天综合网站| 亚洲色欲色欲综合网站| 久久99精品久久久久久综合| 综合久久一区二区三区 | 婷婷久久综合九色综合九七| 亚洲国产综合精品| 亚洲国产成+人+综合| 人人妻人人狠人人爽天天综合网| 国内偷自视频区视频综合| 精品亚洲综合久久中文字幕| 99久久综合狠狠综合久久止| 久久99精品久久久久久综合| 亚洲国产精品综合一区在线| 色综合久久最新中文字幕| 色综合91久久精品中文字幕| 区三区激情福利综合中文字幕在线一区亚洲视频1 | 婷婷亚洲综合五月天小说在线| 亚洲国产综合AV在线观看| 欧美日韩综合一区二区三区|